高级检索

天然气输气场站噪声特征分析及健康风险评估

Noise Characteristics Analysis and Health Risk Assessment of the Natural Gas Transmission Station

  • 摘要: 为了解天然气输气场站运行过程中噪声污染及其可能对场站工人的健康影响,本研究对某天然气输气场站内和厂界的噪声声压级及倍频程进行了24小时连续监测,同时分析了输气量变化对噪声产生的影响,计算了昼夜班工人的累积噪声暴露量(Cumulative Noise Exposure, CNE)和伤残调整寿命年(Disability-Adjusted Life Year,DALY)。研究结果显示,输气场站内噪声的等效连续声压级昼间高于夜间,且产生的噪声属于宽频噪声,16 Hz~125 Hz的低频段噪声在短距离内难以衰减。管道结构确定且流量处于一定范围内时,管道的输气量与噪声声压级存在线性关系(R2=0.79)。受交通噪声等背景噪声的影响,厂界西侧和南侧噪声监测值均无法达到《工业企业厂界环境噪声排放标准》(GB 12348-2008)2类声环境功能区所规定的限值。场站噪声会对工人的健康产生一定的影响,工人所受的累积噪声暴露量受作业区噪声声压级和作业时间的影响,当噪声强度相同时各功能区工人的年龄越小或工龄越长,伤残调整寿命年越大。

     

    Abstract: In order to investigate the noise pollution characteristics of natural gas transmission stations and their potential impacts, sound pressure levels and octave-band spectra were measured both inside the station and at its boundary. A 24-hour continuous monitoring campaign was conducted; the influence of variations in gas throughput on noise emission was analyzed; and cumulative noise exposure and Disability-Adjusted Life Years (DALYs) were calculated for day-shift and night-shift workers. Results show that the equivalent continuous sound pressure level (LAeq) inside the station is higher during daytime than nighttime, and the dominant noise is broadband in nature. Low-frequency noise (16–125 Hz) exhibits poor attenuation over short distances. When pipeline geometry is fixed and flow velocity remains within a certain range, a linear relationship exists between pipeline gas throughput and overall sound pressure level (R2 = 0.79). Due to interference from background noise—particularly traffic noise—the measured noise levels at the western and southern boundaries exceed the limits stipulated for Class 2 acoustic environment functional zones in the *Emission Standard for Industrial Enterprise Boundary Noise* (GB 12348–2008). For a given noise intensity, DALYs increase with younger worker age or longer duration of employment in each functional area.

     

/

返回文章
返回