高级检索

一种基于量热法的平面换能器声功率测量的方法

Measurement of acoustic power of piston transducer based on calorimetry

  • 摘要: 介绍了一种基于量热法的平面换能器声功率测量的方法。先将超声辐射入真空绝热容器内的蓖麻油中,使其温度升高。用热电偶并联测量蓖麻油的平均温升值,计算出蓖麻油所吸收的热能,进而求得换能器的声功率。测量结果表明,在换能器两端电压峰峰值为120V时,用本方法重复10次测得声功率的平均值为5.09W,相应的用辐射力法测得声功率的平均值为6.06W,两者相差16%。该方法的其综合不确定度为±9.3%。此方法使用设备简单且准确性较好,是超声功率测量的一种简单有效的途径。

     

    Abstract: In this paper,a method for measuring acoustic power of plane piston transducer based on calorimetry is presented.When the transducer radiates ultrasound into castor oil,the temperature of castor oil will rise.Using 10-channel parallel thermocouples to measure the average temper-ature rise,energy absorbed by castor oil can be obtained.Acoustic power radiated from the tran-sducer can then be calculated.In this paper,the measurement results from the radiation force method are used as a reference.When the peak-to-peak drive voltage of the transducer is 120 V,average of the results obtained using the proposed method and the radiation force method are 5.09 W and 6.06 W,respectively,with a difference of 16%.The overall uncertainty of the method is 9.3%.The method is simple,economical,practical and accurate.Therefore it is a usefule approach to measure acoustic power of plane piston transducer.

     

/